• S1GE10LHMA2S6 Stenner Econ LD Series Metering Tank System
  • Stenner S1GE10LHMA2S6 Econ LD Series Peristaltic Metering Pump
  • S1GE10LHMA2S6 Stenner Econ LD Series Metering Pump Dimensions
  • E10FXAA1S6 Stenner Pumps Econ Series Tank System Dimensions

Image shown may not be actual product

Stenner Pumps

S1GE10LHMA2S6

0 reviews

Stenner S1GE10LHMA2S6 Econ LD Series Low Dose Peristaltic Metering Tank System. 120V, 60 Hz, 17 RPM, 24VDC Brushless Motor. 15 Gallon UV Gray Polyethylene Tank, Polycarbonate Housing, 0.25" (1/4") UV Black Santoprene Suction & Discharge Tubing, 50:1 Turndown Ratio. 80 PSI Maximum Pressure, 2.4 oz/hr Maximum Flow, 25 ft. Vertical Suction Lift, 50 CPS Maximum Viscosity, and 104°F Maximum Operating Temperature.

$709.95

Ships within 1 business day (in-stock items). Delivery typically 1–5 business days.

Item: S1GE10LHMA2S6

S1GE10LHMA2S6

Stenner S1GE10LHMA2S6 Econ LD Series Low Dose Peristaltic Metering Tank System. 120V, 60 Hz, 17 RPM, 24VDC Brushless Motor. 15 Gallon UV Gray Polyethylene Tank, Polycarbonate Housing, 0.25" (1/4") UV Black Santoprene Suction & Discharge Tubing, 50:1 Turndown Ratio. 80 PSI Maximum Pressure, 2.4 oz/hr Maximum Flow, 25 ft. Vertical Suction Lift, 50 CPS Maximum Viscosity, and 104°F Maximum Operating Temperature.

Connection Size0.25" (1/4")
Cord Length6 ft. (1.8 m)
Discharge NPT (Inches)0.25" (1/4") UV Black Tubing
Housing MaterialPolycarbonate
Hz60 Hz
Includes3 Connecting nuts 1/4", 3 Ferrules 1/4", 1 Duckbill check valve, 1 Weighted suction line strainer 1/4", 1 20' Roll suction/discharge tubing 1/4" white OR 6 mm White Europe, 1 Additional pump tube, 1 Manual
Maximum Flow (GPH)2.4 oz/hr
Maximum Operating Temperature104°F (40°C)
Maximum Pressure (PSI)80 PSI (5.5 Bar)
Maximum Viscosity (CPS)50 CPS
Max Suction Lift25 ft. (7.6 m) Vertical Lift, Based on Water
Motor Type24VDC, Brushless
Product NotesSelf-Priming, Variable Speed
Quick Specs15G G TANK/ LD PUMP 2.4OZ/HR 5.5/80PSI 120V/60HZ 1/4" BLK
Speed (RPM)17 RPM
Suction NPT (Inches)0.25" (1/4") UV Black Tubing
Tank Size (Gal. / Ltr.)15 Gallon UV Gray Polyethylene Tank
Tube MaterialSantoprene (FDA Approved)
Turn Down Ratio50:1
TypeTank System
Valve / Seat / O-RingSantoprene (FDA approved) or FKM (NSF approved) Duckbill Check Valve
Voltage120V

Econ LD Series Low Dose Peristaltic Metering Pumps Information

Accurate Low-Dose Chemical Injection Made Easy

The Stenner Econ LD Series is designed for applications where precise chemical dosing is essential. Whether injecting flocculants, coagulants, anti-scalants, sanitizers, or other treatment chemicals, the Econ LD delivers dependable low-volume metering in a compact and easy-to-maintain package.

Unlike many standard metering pumps, the Econ LD is specifically engineered for low-flow accuracy. With injection rates as low as 0.04 oz/hr and a wide 50:1 adjustment range, users can make precise output changes without sacrificing reliability or consistency.

Built for Accurate Performance

The Econ LD features a variable-speed design controlled by an adjustable potentiometer, allowing operators to easily fine-tune chemical feed rates to match system requirements.

Performance highlights include:

– Adjustable output from very low feed rates to 50.7 oz/hr

– 50:1 turndown capability

– Output reproducibility of ±2%

– Continuous-duty operation

– Maximum working pressure up to 80 PSI

Designed for Reliability

Built with a long-life brushless motor and enclosed housing, the Econ LD is intended for dependable operation in both indoor and outdoor environments. The pump is self-priming, capable of running dry, and suitable for pumping off-gassing solutions.

Additional benefits include:

– Brushless motor for long service life

– Self-priming operation up to 25 feet

– Indoor and outdoor installation capability

– Compact footprint

– Quiet operation

– Wall-mountable design

Easy Maintenance

Routine service is simplified through Stenner's patented quick-release pump head. Pump tube replacement can be performed without tools, helping reduce maintenance time and system downtime.

Tank System Options

For easier installation, the Econ LD is available factory-mounted on solution tanks in:

– 7.5-gallon capacity

– 15-gallon capacity

– 30-gallon capacity

UV gray tanks are available for outdoor use, while white tanks are available for indoor installations.

Ideal Applications

The Econ LD is particularly well suited for:

– Flocculant dosing

– Coagulant injection

– Anti-scalant treatment

– Sanitizer feed systems

– Water treatment processes

– Low-volume chemical metering applications

For facilities that require highly accurate, low-volume chemical injection, the Stenner Econ LD Series provides a dependable solution with precise output control, simple maintenance, and long-term reliability.


Categories

0 Reviews

Add a Review

You need to sign in to add a review.

TypeTitleLink

Stenner Econ LD Series Peristaltic Metering Pumps Brochure

View

Stenner Econ LD Series Peristaltic Metering Pumps Technical Datasheet

View

Stenner Pumps Tank System Technical Datasheet

View

Stenner Econ LD Series Peristaltic Metering Pumps Operator's Manual

View

Stenner Econ Series Pumps Mounting Kit Instruction Manual

View

Stenner Pumps Tank System Installation Manual

View

Stenner Pumps Classic, Econ, S Series Tank System Assembly Instructions

View

Repair Parts for S1GE10LHMA2S6

Productqty.shippingprice
EC30M-2

EC30M-2

Ships in 3 $34.08
EC350

EC350

Ships in 3 $21.57
EC355

EC355

Ships in 3 $10.79
EC310

EC310

Ships in 3 $91.69
EC302

EC302

Ships in 3 $9.17
EC303

EC303

Ships in 3 $13.48
EC304

EC304

Ships in 3 $13.48
STS15GC

STS15GC

Ships in 3 $225.75
0 items selected.Add items to cart

HD Product Demos & More

Stay tuned for releases of new product reviews and videos on our YouTube channel!

Secure Online Shopping

We take your privacy and security serious. Feel safe when shopping in our online marketplace.

  • Burks
  • LMI
  • Berkeley
  • Grundfos
  • Goulds Water Technology

Still have questions?Call our Pump Hotline at 1-800-810-1053

sign up and save.

Some content