Image shown may not be actual product
111-00740-0000
Pumpworks 111-00740-0000 PWA-LF Series ANSI B73.1 Compliant Low-Flow Centrifugal Process Pumps, Model: PLF,1x2x10,3R3,F,1BB0,CCS,STD. Group 3, Size 1 x 2 x 10, 2" Suction, 1" Discharge 300# Raised Face Flanged Connections. Threaded CS Impeller, Big Bore Cover, Flush (Discharge) Tap, No Bushing. CS Case, SS Shaft, Aramid Fiber Gasket, Teflon Seal, Oil w/ ISOMAG Lubrication. Bare Pump Only, Does Not Include Motor.
- Overview
- Series Info
- Reviews
- Literature/Manuals
111-00740-0000
Pumpworks 111-00740-0000 PWA-LF Series ANSI B73.1 Compliant Low-Flow Centrifugal Process Pumps, Model: PLF,1x2x10,3R3,F,1BB0,CCS,STD. Group 3, Size 1 x 2 x 10, 2" Suction, 1" Discharge 300# Raised Face Flanged Connections. Threaded CS Impeller, Big Bore Cover, Flush (Discharge) Tap, No Bushing. CS Case, SS Shaft, Aramid Fiber Gasket, Teflon Seal, Oil w/ ISOMAG Lubrication. Bare Pump Only, Does Not Include Motor.
| ANSI Designation | A05 |
| Base Model Number | PLF |
| Bushing | No Bushing |
| Case Gasket | Aramid Fiber |
| Casing Material | CS |
| Cover Type | Big Bore |
| Discharge NPT (Inches) | 1" |
| Flange | 300# Raised Face |
| Group | Group 3 |
| Impeller Material | CS |
| Impeller Seal | Teflon |
| Impeller Style | Threaded |
| Lubrication | Oil w/ ISOMAG |
| Model Series | PWA Low Flow |
| Motor Shaft Material | SS |
| Part Type | Bare Pump |
| Pump Size | 1 x 2 x 10 |
| Quick Specs | PLF,1x2x10,3R3,F,1BB0,CCS,STD |
| Shaft Sleeve Material | SS |
| Size | LT |
| Suction NPT (Inches) | 2" |
| Tap Connections | Flush (Discharge) |
| Type | with Sleeve |
PWA Low Flow ANSI Process Pumps Information
| Features & Benefits | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
When a customer is looking at the PWA-LF (Low Flow) series, they are likely dealing with a specific engineering challenge: Low Flow/High Head applications. Standard ANSI pumps are designed for high-volume movement.When you try to run a standard pump at very low flows, it vibrates, builds up heat, and suffers from "radial thrust" that snaps shafts and kills seals. The PWA-LF is the surgical tool designed to solve those specific problems. 1. The Engineering Difference: Circular VoluteUnlike a standard pump that has a spiral-shaped (volute) casing, the PWA-LF features a precisely machined circular volute. The Benefit: In a standard pump, running at low flow creates an unbalanced pressure distribution around the impeller. This "radial load" pushes the shaft to the side. The PWA-LF Solution: The circular casing equalizes the pressure around the impeller. This eliminates shaft deflection, which is the #1 cause of mechanical seal failure in low-flow environments. 2. The Radial Vane ImpellerThe PWA-LF uses a specialized multi-vane open radial impeller. Reduced Pulsation: Standard impellers create "pulsations" when choked down to low flows. The radial vane design provides smooth, stable hydraulics. Exceptional Strength: These impellers are fully shrouded to provide maximum vane strength, ensuring they don’t flex or fatigue under the high pressures often associated with low-flow service. Integrated Balance Holes: These reduce thrust loads on the bearings, extending the life of the entire power end. 3. Performance StabilityCustomers need to know that the PWA-LF provides a wider "allowable operating range." If you run a standard pump too far to the left of its performance curve (at low flow), you deal with "recirculation" and heat.The PWA-LF is hydraulically stable even at flows as low as 1 GPM, allowing for precise process control without damaging the equipment. 4. Common "Killer" ApplicationsThe PWA-LF is the go-to choice for specific industrial scenarios:
5. Shared Benefits with the Standard PWAEven though the hydraulics are specialized, the PWA-LF still carries all the premium PumpWorks "Standard" features: Carbon Steel Case: ASTM A216 WCB is standard (not brittle iron). 5-Year Unconditional Warranty: On the Power Frame. 100% Interchangeable: The PWA-LF "Wet End" fits on standard ANSI B73.1 power ends and baseplates. You can swap a problematic standard pump for a PWA-LF without moving your motor or piping. Summary: Why choose the LF?
Are you currently experiencing high vibration or frequent seal failures on a pump that is being throttled back? I can help you check the curve to see if a PWA-LF is the correct hydraulic fit. | |||||||||||||||
| Performance Specifications | |||||||||||||||
Test Flows: Up to 7,500 GPM | |||||||||||||||
| Typical Industries & Ideal Applications | |||||||||||||||
|
Categories
Basic Chemicals
29822 productsFood & Beverage Services
23601 productsIndustrial
30503 products
Manufacturing
30503 productsMining
30503 productsOil & Gas
30503 productsPetrochemical
22920 productsPower Generation
29822 productsPulp & Paper
30503 productsWaste Treatment
29822 products
HD Product Demos & More
Stay tuned for releases of new product reviews and videos on our YouTube channel!
Follow Us and Save
Check our Social Media for new product announcements and exclusive specials for our followers.
Secure Online Shopping
We take your privacy and security serious. Feel safe when shopping in our online marketplace.

0 Reviews
Add a Review
You need to sign in to add a review.