LMI Pumps E711-362SI Series E7 Explosion Proof Metering Pumps, 2.5 GPH @ 150
LMI Pumps E711-362SI Series E7 Explosion Proof Metering Pumps, 2.5 GPH @ 150
Connections / Discharge (Inches) | Tubing PE 3/8" O.D. |
Diaphragm | Fluorofilm |
Explosion Proof | Yes |
Flow Control | Pulse Input with Dual Manual Control |
Head / Fittings | Molded PVDF / PVDF |
Hz | 50/60 |
Includes | 4FV-Four Function Valve (anti-siphon, back pressure, priming/pressure release and pressure relief), Tubing, Foot Valve and Strainer, Ceramic Foot Valve Weight, 1/2" NPT Male Injection Check/Back Pressure Valve, and Instruction Manual |
Maximum Flow (GPD) | 60 |
Maximum Flow (GPH) | 2.5 |
Maximum Pressure (PSI) | 150 |
Maximum Strokes Per Minute | 100 |
Maximum Viscosity (CPS) | 400 |
Turn Down Ratio | 600:1 |
Valve Balls | .375 Ceramic |
Valve / Seat / O-Ring | PVDF / Polyprel |
Voltage | 115 |
General Description |
---|
LMI Series E7 (Explosion Proof) chemical metering pumps shall be positive displacement, Liquifram type pumps that are UL and CUL approved. Pumps shall be equipped with UL listed, Class I, Division 1, Groups C and D; Class II, Division 1, Groups E, F and G Drive Assembly. Output volume shall be adjustable while pumps are in operation from zero to maximum capacity. |
Pump Controls |
Adjustment shall be by means of readily accessible dial knobs, one for changing stroke length and the other for changing stroke frequency. Both knobs are to be located opposite the liquid handling end. |
Drive Assembly |
The pump drive shall be totally enclosed with no exposed moving parts. Pump drives shall be UL listed Class I, Groups C and D and Class II, Division 1, Groups E, F and G. Solid state electronic pulser shall be fully encapsulated with no exposed printed circuit etch and with quick connect terminals at least 3/16" (4.75 mm) wide. Electronics shall be housed in chemical resistant enclosure at the rear of the pump for maximum protection against chemical spillage. Average electrical power consumption shall not exceed 44 watt hours per hour under full speed and maximum pressure conditions. Pump weight shall not exceed 41 lbs (18.6 kg). |
Pressure Relief |
To eliminate need for pressure relief valve, Liquifram shall automatically stop pulsating when discharge pressure exceeds pump pressure rating by not more than 35%. |
Materials of Construction |
Chemical metering pump housing shall be of urethane painted cast aluminum and urethane painted cast iron. All exposed fasteners shall be stainless steel. Valve seat and seal ring shall be renewable by replacing only the combination seat-seal ring or cartridge valve assembly. |
Check Valve / Tubing Connections |
A total of 16 ft (4.9 m) of tubing shall be provided per pump complete with compressing connections (on models with tubing connections). A foot valve with integral one piece strainer shall be provided for the suction line (on non-high viscosity models with tubing connections), and an injection check/back pressure valve with 1/2" NPT male connection for the injection point (on models with tubing connections). |
Chemical Metering
39812 productsType | Title | Link | |
---|---|---|---|
LMI Series E7 Electronic Metering Pump Data Sheet | View | ||
Series E7 Electronic Metering Pump Specification Sheet | View | ||
LMI Pumps E7 Drive Assembly Exploded View Parts Diagram | View | ||
LE 3X2SX LE 3X8SX LMI Pump Liquid End Sheet Parts Exploded View Diagram | View | ||
LE 362SI LMI Pump Liquid End Sheet Parts Exploded View Diagram | View |
Stay tuned for releases of new product reviews and videos on our YouTube channel!
Check our Social Media for new product announcements and exclusive specials for our followers.
0 Reviews
Add a Review
You need to sign in to add a review.