• Pulsatron Pumps Model LTD4SB-PTCA-XXX Chemical Metering Pump
  • Pulsatron Pumps Model LTD4SB-PTCA-XXX Chemical Metering Pump Back View

Image shown may not be actual product

Pulsatron

LTD4SB-PTCA-XXX

0 reviews

Pulsatron Model LTD4SB-PTCA-XXX Metering Pump, Series ET, 22 GPD @ 150 PSI, Dual Manual Control with Water Meter Input, 230 VAC, FPP/TFE/CDBL.50T

Item: LTD4SB-PTCA-XXX

LTD4SB-PTCA-XXX

Pulsatron Model LTD4SB-PTCA-XXX Metering Pump, Series ET, 22 GPD @ 150 PSI, Dual Manual Control with Water Meter Input, 230 VAC, FPP/TFE/CDBL.50T

Accessories• KOP Kits • Gauges • Dampeners • Pressure Relief Valves • Tanks • Pre-Engineered Systems • Process Controllers
Connections / Discharge (Inches)Tubing 1/2" OD
Connection TypeTubing
DiaphragmPTFE faced CSPE
Discharge NPT (Inches).38" x .50"
Flow ControlManual On/Off
Flow Rate LPH3.4
GPH Flow Limitations (250 SPM)0-3.76
Head / FittingsGFPPL (Polypropylene)
Hz50/60
IncludesA weighted foot valve/strainer assembly, a bleed valve assembly, a 1/2" NPT male injection fitting/back pressure check valve assembly, 4' suction tubing, 4' bleed/return tubing, 8' discharge tubing and Owners Manual.
Liquid End ConfigurationGFPPL (Polypropylene) / TFE / Ceramic
Maximum Flow (GPD)22
Maximum Flow (GPH)0.9
Maximum Pressure (PSI)150
Maximum Viscosity (CPS)1000
OptionsStandard Pump - No Additional Options
Phase1 Ph (Single Phase)
Pressure Rating BAR10
Suction NPT (Inches).38" x .50"
Turn Down Ratio10:1
Valve BallsCeramic
Valve / Seat / O-RingTeflon
Viscocity1000 up to 3000 cps w/ SS balls
Voltage230

ET Series Information

Features & Benefits
Dual Manual Control with Water Meter Input: Stroke length is manually adjustable, stroke frequency is manually adjustable. In count modes (4), pump will run for a specified time (1-200 seconds or 12 sec to 20 minutes) for every (1 or 10) water meter contact inputs. 100:1 max turndown.

Pulsatron Series ET Chemical Metering Pump by Pulsafeeder

• Complete Timer Control in one unique package.
• Simple Mode Select knob, Stroke Length knob, and Stroke Rate knob.
• Two Selectable Time Base Settings.
• Water Meter Input. Activate pump on 1 or 10 counts.
• Isolated Dry Contact Water Meter Output.
• Highly Reliable timing circuit.
• Isolated from Earth Ground.
• Circuit Protection against voltage and current upsets.
• Solenoid Protection by thermal overload with auto-reset.
• Water Resistant, for outdoor and indoor applications.
• Internally Dampened To Reduce Noise.
• Guided Ball Check Valve Systems, to reduce back flow and enhance outstanding priming characteristics.
• Few Moving Parts and Wall Mountable.
• Safe & Easy Priming with durable leak-free bleed valve assembly (standard).
• Reliable metering performance.
• Rated "hot" for continuous duty.
• Leak-free, sealless, liquid end.
General Description
Pulsafeeder PULSAtron PLUS Series ET chemical metering pumps are positive displacement, diaphragm type pumps with Integrated Feed Control per Water Meter Input. Output volume is adjustable while pumps are in operation from zero to maximum capacity. The PULSAtron PLUS Series ET pump was designed to feed chemical in response to a water meter input. Typical applications include inhibitor feed for an open air-cooling tower. The Series ET provides everything you need in one unique, compact package to create a simple and cost effective metering system. The Series ET counts pulses from a water meter. When the count exceeds a set value (either 1 or 10), the pump starts. The pump will continue to run for an adjustable time period. There are two time ranges - either 2 to 200 seconds or 12 seconds to 20 minutes. The setting is made by selecting a time base value (200 seconds or 20 minutes) and then setting the time base percentage from 1 to 100%. The pump includes both input and output water meter connections at the front panel. The output connection provides an isolated dry contact output of the water meter contact to operate additional pumps or tim ers off the same water meter. There is no need for a separate timer. All timer functions are integrated into the pump eliminating the expense of purchasing an installing another piece of equipment. There are no complicated menu structures. Simply select the desired mode on the front panel and connect the water meter input. There are two selectable time base settings. Choose the time base appropriate for your applications and set the percent value to run the amount of time you desire.
Pump Controls
Adjustment is by means of readily accessible dial knobs, one for changing stroke length and the other for changing stroke frequency (modes 1 & 2) or changing percent of time (modes 3 through 6). Both knobs are located opposite the liquid handling end. Automatic control via water meter input. Standby-Manual-Count/Time switch.
Drive Assembly
The pump drive is totally enclosed with no exposed moving parts. Electronics are housed in chemical resistant enclosure at the rear of the pump for maximum protection against chemical spillage. Average electrical power consumption is 130 Watts.
Materials of Construction
Chemical metering pump housing shall be of chemically resistant PBT thermoplastic. All exposed fasteners are stainless steel. Valve seat and seal ring are renewable by replacing the cartridge valve assembly.
Engineering Data - Materials
Pump Head Materials: GFPPL, PVC, PVDF, 316 SS
Diaphragm: PTFE-faced CSPE-backed
Available Seat O-Rings: PTFE, CSPE, Viton
Available Ball Types: Ceramic, PTFE, 316 SS, Alloy C
Available Fitting Material: GFPPL, PVC, PVDF
Bleed Valve: Same as fitting and check valve selected (except 316 SS)
Available Tubing: Clear PVC, White PE

Important Material Codes:
GFPPL = Glass-filled Polypropylene
PVC = Polyvinyl Chloride
PE = Polyethylene
PVDF = Polyvinylidene Fluoride
PTFE = Polytetrafluoroethylene
CSPE = Generic formulation of Hypalon, a registered trademark of E.I. DuPont Company.
Viton is a registered trademark of E.I. DuPont Company.
PVC wetted end recommended for sodium hypochlorite.
Controls
• Manual Stroke Rate
• Manual Stroke Length
• External Pacing - Optional
Control Options
Available Control Options:

• Manual On/Off
Engineering Data - Tech
Reproducibility: +/- 2% at maximum capacity
Controls:
Standby
200 sec/count
20 min/count
On
200 sec/10 count
20 min/10 count
Stroke Length Turn-Down Ratio: 10:1

Power Input:
115 VAC / 50-60 HZ / 1 Phase
230 VAC / 50-60 HZ / 1 Phase
5 Amp max

Power Output: 120VAC or 250VAC @ 50/60 HZ, 5A max
Chemical Compatibility
Liquid End Code / Chemical

PHC - AMMONIA, 10%, CITRIC ACID, 10 - 20%, SODIUM HYDROXIDE, 0 - 50%, SODIUM SILICATE, SODIUM SULFATE, SODIUM SULFIDE
ATS - DEAE - Steamline Treatment
PTC - FERRIC SULFATE, HYDROCHLORIC ACID, 0 - 37%, LACTIC ACID, POTASSIUM CHLORIDE, POTASSIUM PERMANGANATE SODIUM BI-CARBONATE, SODIUM BI-SULFATE, SODIUM CARBONATE, SODIUM NITRATE, SULFURIC ACID, 0 - 10%, SULFURIC ACID, 10 - 75%
PTT - FLUOSILICIC ACID, HYDROFLUOSILICIC ACID, 20%
KTT - HYDROCHLORIC ACID, 37 - 100%
PVC - NITRIC ACID, 0 - 20%,
VVC - SODIUM HYPOCHLORITE
KTC - PHOSPHORIC ACID, 0 - 100%, SULFURIC ACID, 95 - 100%

Categories

0 Reviews

Add a Review

You need to sign in to add a review.

TypeTitleLink

Pulsatron Series ET Electronic Metering Pump Brochure

View

Pulsatron Series ET Electronic Metering Pump Datasheet

View

Pulsatron Series ET Electronic Metering Pump Product List

View

Pulsatron Series ET Electronic Metering Pump Parts

View

HD Product Demos & More

Stay tuned for releases of new product reviews and videos on our YouTube channel!

Secure Online Shopping

We take your privacy and security serious. Feel safe when shopping in our online marketplace.

  • Burks
  • LMI
  • Berkeley
  • Grundfos
  • Goulds

Still have questions?Call our Pump Hotline at 1-800-810-1053